Sussex roof-window specialists

VELUX & Roof Window Installation Across Sussex

Bring daylight and fresh air into a loft, extension, stairwell or upper-floor room with a roof window that is properly integrated into the roof. Bespoke Roofing & Renovations installs new windows, replaces older units and investigates leaks around tiled and slated roof-window openings.

Two professionally installed roof windows in a finished tiled Sussex roof
Completed roof-window layout
In-house scaffoldingAccess coordinated with the roofing programme
Drone-assisted surveysUseful views where conditions and location allow
FMB memberFederation of Master Builders profile available
£10m public liabilityClear written scopes and quotations
New VELUX and roof windows

Plan the opening, not just the window

A successful installation depends on the roof pitch, window position, rafter layout, roof covering, correct flashing set and the internal reveal. We assess these together before defining the scope.

  • Careful removal and reinstatement of surrounding tiles or slates
  • Opening formed and roof timbers trimmed or strengthened where required
  • Compatible flashing, underfelt collar and drainage details
  • Insulation around the frame to reduce cold bridging
  • Internal plasterboard finishing included where agreed
  • Safe access planned using in-house scaffolding where appropriate

Important: forming a new opening can involve structural work. The quotation should state what is included, what needs approval and whether internal decoration is excluded or included.

Finished Sussex loft interior with an open roof window and clean plastered reveal
A finished internal result showing the importance of window position, daylight and a neatly formed reveal.
Choosing the right roof window

Operation, position and roof covering all matter

The best option depends on how the room will be used, whether the window is within reach, the view you want and any planning or heritage constraints. Product pitch ranges and flashing compatibility must be confirmed for the exact model.

Popular choice

Centre-pivot

A practical, easy-to-operate option for many lofts, bathrooms and stairwells. The sash rotates through the centre of the frame, making the handle position and furniture layout important.

Clearer outlook

Top-hung

Opens outwards from the top and can provide a more uninterrupted view when installed at an appropriate height. It suits some habitable loft rooms but is not automatically right for every pitch.

Hard to reach

Electric or solar

Useful over stairs, landings or high ceilings. Compatible products may offer wall-switch or remote operation and rain-sensor closure; power and product requirements are agreed before installation.

Period property

Conservation style

Designed to sit more discreetly within a roof and available for some heritage settings. Planning and listed-building requirements still need checking for the individual property.

More daylight

Multiple windows

Side-by-side or vertically combined windows can make a larger room feel brighter. Rafter positions, structural trimming, spacing and compatible combination flashings must be planned together.

Privacy or comfort

Glazing and blinds

Consider thermal performance, safety glazing, noise reduction, privacy, solar control and blackout requirements. Bathroom locations also need a finish suitable for higher humidity.

Weatherproofing detail

How a roof window connects to the roof

The visible window is only one part of the installation. Water must be directed around the frame, the underlay must connect correctly, the roof covering needs the right clearances and the gap around the window should be insulated.

Schematic roof-window weatherproofing junction A labelled diagram showing roof tiles, drainage gutter, flashing, roof-window frame, underfelt collar, roofing underlay and insulation around the window. Drainage gutter Tiles or slates Window frame Flashing system Underfelt collar Roofing underlay Insulated gap around frame
Schematic only: the exact flashing, collar, drainage and installation details depend on the selected roof window, roof covering, pitch and manufacturer instructions.

VELUX describes its BFX underfelt collar as the connection between the window, battens and roofing underfelt, while its BDX insulation collar is intended to reduce heat loss and cold bridging. We specify compatible components for the chosen product rather than treating every roof as the same.

Leaking VELUX and roof windows

Water staining does not always mean the window has failed

Rain penetration, internal condensation and a failed glazing unit can look similar from inside. A useful inspection considers when the mark appears, the condition above and around the frame, the roof covering and the ventilation of the room.

Roof-window water diagnosis flow A decision diagram distinguishing rain-linked water entry, persistent fogging between glass panes and internal condensation. What do you notice? Record when and where it appears Appears after rain Check flashings, tiles/slates, underlay and drainage channels Moisture on room side Check humidity, ventilation, insulation and cold bridges Fogging between panes Likely sealed glazing-unit issue; assess parts or replacement Inspect before deciding to repair or replace The correct remedy follows the evidence—not the stain alone.
Customer guide to likely investigation routes. It is not a remote diagnosis; safe roof-level inspection may still be required.
FindingRepair may be practicalReplacement may be better
External leakA local flashing defect, blocked channel or isolated damaged tile/slate is confirmed.The frame is deteriorated, several details are failing or the previous installation is fundamentally unsuitable.
GlazingA serviceable part or glazing unit is available and the frame remains sound.The glazing has failed, parts are obsolete, or thermal performance and seals are poor throughout.
OperationAdjustment or a replaceable component resolves closing or locking problems.The sash/frame is distorted, rotten or no longer capable of reliable operation.
Roof renewalThe window is relatively modern and compatible with the new roof build-up.The surrounding roof is already being stripped and the old unit is near the end of its useful life.
From enquiry to completion

A coordinated roof-window installation

The precise sequence changes for a new opening, replacement or repair, but customers should always know what is being supplied, how the roof will be accessed and where the internal finish stops.

Initial details

Send the property location, room use, roof photographs and a picture of the intended internal position where safe.

Roof assessment

We consider roof covering, pitch, access, window position and whether a drone-assisted view would add useful information.

Window specification

Size, opening style, finish, glazing, operation and compatible flashing components are agreed.

Written quotation

The roofing work, access, structural allowance, internal finishing, price and applicable guarantee are set out clearly.

Approvals

Planning, listed-building and building-control requirements are identified for the customer before applicable work proceeds.

Safe access

Where scaffolding is required, our in-house team can coordinate it with the installation programme.

Installation

The opening, frame, collars, flashing, tiles or slates and insulation are completed to the agreed specification.

Checks and handover

The window is operated, external details checked and the work area cleared before handover.

TotalBuilding Control
Planning and compliance

Check the property and the complete project

Some roof-window installations fall within permitted development limits, but that should not be assumed for every home. The position, projection, highest roof point, side-facing glazing, property type and local restrictions all matter. Flats, listed buildings, conservation settings and properties affected by an Article 4 direction may need different consent.

Building Regulations can also apply, particularly where rafters are altered, a loft becomes habitable, escape provisions change or thermal performance is affected. Where formal oversight is required for the agreed project, we can coordinate with Total Building Control and include the relevant arrangement in the quotation.

Roof windows during re-roofing

A sensible time to replace an ageing window

When tiles or slates are already being removed, a roof window can be incorporated into the new roofing membrane and batten layout. This often provides cleaner access to the full junction and avoids disturbing a newly completed roof later.

We can quote roof-window work alongside roof-lining replacement, pitched roof replacement or wider renovation work. If an existing window is being retained, its condition, size and compatibility with the proposed roof build-up should be checked before the roof is stripped.

A useful quotation should say: which window and flashing set are included; whether structural trimming, internal plasterboard, decoration, electrical work and Building Control are included; and what happens to surrounding roof coverings.

Bespoke Roofing roof-window flashing installation in progress on a tiled Sussex roof
A Bespoke roof-window installation in progress, showing the window, flashing apron, roofing membrane, battens and surrounding concrete tiles before completion.
Drone-assisted roof surveys

Useful context without pretending a drone sees everything

Where conditions, airspace and the property allow, drone photographs can show the roof-window position, slipped or cracked surrounding coverings, obvious flashing defects and the wider drainage route. They are particularly useful on tall or difficult-to-view roofs.

What it can show

External context, visible damage, debris around the head of the window and the relationship to ridges, valleys and gutters.

What it cannot confirm

Hidden membrane laps, insulation gaps, timber condition or the precise internal source of moisture without closer investigation.

How we use it

As part of the evidence for the next step—not as an automatic substitute for safe hands-on inspection where that is necessary.

East and West Sussex

Roof-window installers across Sussex

We work on tiled and slated properties from the coast to inland Sussex towns, with the appropriate local telephone number shown in your quotation.

  • Brighton
  • Hove
  • Worthing
  • Shoreham
  • Lancing
  • Steyning
  • Storrington
  • Henfield
  • Pulborough
  • Horsham
  • Burgess Hill
  • Haywards Heath
  • Lewes
  • Newhaven
  • Peacehaven
  • Littlehampton
Roof-window questions

Frequently asked questions

Do I need planning permission for a VELUX roof window?

Many householder roof-window installations can fall within permitted development limits, but this depends on the design, projection, position and property. Different considerations apply to listed buildings, flats, maisonettes, conservation settings and homes affected by local restrictions. Check the Planning Portal and the relevant local planning authority before work begins.

Do Building Regulations apply to a new roof window?

They may. Structural alterations to rafters, thermal performance, safety glazing, ventilation, fire escape and the creation of habitable loft accommodation can all be relevant. The requirement depends on the complete project, not merely the brand of window.

Can you replace an old window without enlarging the opening?

Often, a suitable replacement can use the existing opening, but the current window code, size, roof pitch, surrounding roof condition and available replacement products must first be checked. Internal lining and external flashing changes may still be needed.

Why is water appearing around my roof window?

Possible causes include failed or unsuitable flashings, cracked surrounding tiles or slates, damaged underlay, blocked drainage channels, deteriorated seals, failed glazing, missing insulation or internal condensation. The timing and location of the moisture help direct the inspection.

Can a leaking VELUX window be repaired?

Yes, where the confirmed fault is local and the frame remains serviceable. If the unit is rotten, distorted, obsolete or failing in several places, replacement may offer better value than repeated repairs.

Do you install centre-pivot, top-hung and solar windows?

We can quote a range of manual, electric and solar roof-window options. The suitable model depends on pitch, room use, access, height, roof covering and any planning constraints. Product availability and exact compatibility are confirmed for the individual job.

Can you complete the internal plasterboard finish?

Yes, where agreed. The quotation will state whether insulation, plasterboard, plastering and decoration are included. This avoids uncertainty between the external roofing installation and the final decorated room.

Is it cheaper to install a roof window during a roof replacement?

It can be more efficient because the roof covering, membrane and battens are already being renewed. The opening, collars and flashing can be integrated into the new roof build-up, although structural and internal work still need separate assessment.

Do you provide scaffolding?

Yes. Bespoke Roofing has in-house scaffolding, allowing suitable access requirements to be coordinated with the roof-window work. The quotation will identify the access included.

Can you inspect the roof window by drone?

Where conditions and the location permit, drone photographs can provide useful external context. A drone cannot reveal every hidden defect, so closer safe inspection may still be necessary before a repair scope is confirmed.

Free written quotation

Tell us what you want the room—and roof—to do

For a new window, send photographs of the roof and intended internal position. For a leak, tell us when the water appears and where the staining is located. We will recommend the right next step and provide a clear written quotation for agreed work.

Bespoke Roofing & Renovations Ltd · Sussex roofing and scaffolding · Brighton 01273 447495 · Worthing 01903 958694 · cameron@bespoke-roofing.com
VELUX is a registered trademark of the VELUX Group. Bespoke Roofing & Renovations Ltd is an independent roofing contractor.